Millimeter Wave Products Inc
Millimeter Wave Products Inc

Ka-Band | Micrometer Type Phase Shifter | 26.5GHz – 40GHz

Ka-Band | 26.5 – 40 GHz | Micrometer Type Uncalibrated Phase Shifter 527A/599, Insertion Loss 0.3 dB, Average Power 1 Watt Description: Mi-Wave’s 527 Series Phase Shifters are designed for operation in waveguide sizes from 18 to 220 GHz. This resolution is advantageous since the total travel of the phase shift vane is quite short at high frequencies. The precise micrometer readout enhances setting and repeatability of these devices tested. Each phase shifter

2021-08-09T20:56:56-04:00

W-Band | 75 – 110 GHz | Dial Type Uncalibrated Phase Shifter

W-Band | 75 – 110 GHz | Dial Type Uncalibrated Phase Shifter 525W/387, Insertion Loss 0.5 dB, Average Power 0.6 Watts Description: Mi-Wave’s 525 Uncalibrated an 526 Calibrated Phase Shifters provide phase shifts from 0º to 180º at any frequency within the waveguide band. Designed to maintain reliable performance for accurate test measurements, the firm setting control of these devices maintains stable performance under all normal conditions of unit orientation and test bench

2023-04-07T19:12:29-04:00

V-Band | 50 – 75 GHz | Dial Type Uncalibrated Phase Shifter

V-Band | 50 – 75 GHz | Dial Type Uncalibrated Phase Shifter 525V/385, Insertion Loss 0.4 dB, Average Power 0.8 Watts Description: Mi-Wave’s 525 Uncalibrated an 526 Calibrated Phase Shifters provide phase shifts from 0º to 180º at any frequency within the waveguide band. Designed to maintain reliable performance for accurate test measurements, the firm setting control of these devices maintains stable performance under all normal conditions of unit orientation and test bench

2023-03-29T15:23:35-04:00

U-Band | 40 – 60 GHz | Dial Type Uncalibrated Phase Shifter

U-Band | 40– 60 GHz | Dial Type Uncalibrated Phase Shifter 525U/383, Insertion Loss 0.3 dB, Average Power 1 Watt Description: Mi-Wave’s 525 Uncalibrated an 526 Calibrated Phase Shifters provide phase shifts from 0º to 180º at any frequency within the waveguide band. Designed to maintain reliable performance for accurate test measurements, the firm setting control of these devices maintains stable performance under all normal conditions of unit orientation and test bench vibration.

2023-04-07T19:18:46-04:00

K-Band | 18 – 26.5 GHz | Dial Type Uncalibrated Phase Shifter

K-Band | 18 – 26.5 GHz | Dial Type Uncalibrated Phase Shifter 525K/595, Insertion Loss 0.3 dB, Average Power 1.5 Watts Description: Mi-Wave’s 525 Uncalibrated an 526 Calibrated Phase Shifters provide phase shifts from 0º to 180º at any frequency within the waveguide band. Designed to maintain reliable performance for accurate test measurements, the firm setting control of these devices maintains stable performance under all normal conditions of unit orientation and test bench

2021-08-09T20:57:48-04:00

G-Band | 140 – 220 GHz | Dial Type Uncalibrated Phase Shifter

G-Band | 140 – 220 GHz | Dial Type Uncalibrated Phase Shifter 525G/387, Insertion Loss 1.0 dB, Average Power 0.2 Watts Description: Mi-Wave’s 525 Uncalibrated an 526 Calibrated Phase Shifters provide phase shifts from 0º to 180º at any frequency within the waveguide band. Designed to maintain reliable performance for accurate test measurements, the firm setting control of these devices maintains stable performance under all normal conditions of unit orientation and test bench

2021-08-09T20:58:01-04:00

F-Band | 90 – 140 GHz | Dial Type Uncalibrated Phase Shifter

F-Band | 90 – 140 GHz | Dial Type Uncalibrated Phase Shifter 525F/387, Insertion Loss 0.6 dB, Average Power 0.3 Watts Description: Mi-Wave’s 525 Uncalibrated an 526 Calibrated Phase Shifters provide phase shifts from 0º to 180º at any frequency within the waveguide band. Designed to maintain reliable performance for accurate test measurements, the firm setting control of these devices maintains stable performance under all normal conditions of unit orientation and test bench

2021-08-09T20:58:11-04:00

E-Band | 60 – 90 GHz | Dial Type Uncalibrated Phase Shifter

E-Band | 60 – 90 GHz | Dial Type Uncalibrated Phase Shifter 525E/387, Insertion Loss 0.5 dB, Average Power 0.7 Watts Description: Mi-Wave’s 525 Uncalibrated an 526 Calibrated Phase Shifters provide phase shifts from 0º to 180º at any frequency within the waveguide band. Designed to maintain reliable performance for accurate test measurements, the firm setting control of these devices maintains stable performance under all normal conditions of unit orientation and test bench

2023-04-07T19:34:05-04:00

D-Band | 110 – 170 GHz | Dial Type Uncalibrated Phase Shifter

D-Band | 110 – 170 GHz | Dial Type Uncalibrated Phase Shifter 525D/383, Insertion Loss 0.3 dB, Average Power 1 Watt Description: Mi-Wave’s 525 Uncalibrated an 526 Calibrated Phase Shifters provide phase shifts from 0º to 180º at any frequency within the waveguide band. Designed to maintain reliable performance for accurate test measurements, the firm setting control of these devices maintains stable performance under all normal conditions of unit orientation and test bench

2023-03-29T16:36:03-04:00